WebLa possibilità di misurare con accuratezza la granulometria, la morfologia, l'area superficiale BET, la densità, porosità e l'assorbimento di acqua consente di ottenere informazioni … Web阿里巴巴麦克ASAP2024Plus 2460石英玻璃bet样品管比表面积测试管送样漏斗,为您找到麦克ASAP2024Plus 2460石英玻璃bet样品管比表面积测试管送样漏斗淘宝、天猫、京东、亚马逊同款货源,欲了解更多相关货源详细信息,请点击访问!
Asap 2460 bet
Did you know?
Web2 mar 2024 · the samples was measured using Micromeritics ASAP 2460 BET appa-ratus (Micromeritics ASAP 2460, USA). The Fe K-edge X-ray absorption . spectra were obtained in transmission mode at beamline 17C at ... WebMicroActive for ASAP 2460 2.01 MicroActive for ASAP 2460 Version 2.01 Page 1 Serial # 212 Unit 1 Port 2 Sample: KD-PWSP Operator: Submitter: s/n 212 File: C:\MicroActive for ASAP 2460\data\UCG-K...\KD-PWSP.SMP Started: 2015/06/22 8:12:11 Analysis Adsorptive: N2 Completed: 2015/06/22 15:46:43 Analysis Bath Temp.: -195.800 °C
WebKey Features Features of the ASAP 2460 Surface Area and Porosity Analyzer include: Fully automated modular system for efficient sample screening Servo control facilitates a higher degree of gas management and data point collection High throughput with two-, four-, or six- analysis ports Low surface area and micropore options WebASAP 2420 Multi-Port, ... - BET surface area analyses utilizing six parallel runs can be achieved in as little as 30 minutes. ... gas analyzer ASAP 2460. mercury monitoring pressure. gas analyzer AutoChem II & HP. acid metal …
Web10 apr 2024 · The carbon was also characterized with nitrogen sorption isotherms at a temperature of 77 K using a computer-controlled Micromeritics ASAP 2460 apparatus (Micromeritics Instrument Co., Norcross, GA, USA). These isotherms were used to determine the specific surface area by applying the Brunauer–Emmett–Teller (BET) … http://lab.muchong.com/index.php?ac=detail&op=product&productid=17090122248737
WebThe ASAP 2460 Surface Area and Porosimetry Analyzer is a system designed for high performance and high sample throughput. The base ASAP 2460 is a two-port master control unit wihich is expanded with an …
Web10 mag 2024 · Thermo gravimetric analysis (TGA) was carried out by a Mettler Toledo TGA in the temperature range of 25 to 600 °C at a heating rate of 10 °C min −1 under N 2 atmosphere. The pore structure and distribution was analyzed with Brunauer–Emmett–Teller (BET) method using a Micromeritics ASAP 2460 BET analyzer. Visualized adsorption test sidler rotary damper geared shaftWeb29 set 2024 · 类型: 铂电阻器 (RTD) 精度:±0.10 °C,通过键盘输入 稳定性:每月 ±0.10 °C. 歧管压力传感器. 范围:. 真空至 950 mmHg 工作压力:. 最大 1000 mmHg. 氪气选件 … the pony of shadowsWebASAP 2460 Advantages Fully automated modular system optimized for walk-up sample screening High throughput with two, four, or six independent analysis stations BET … sid lee t shirts